Mining

Why switch to the MICAP-OES 1000?
Learn about other applications:
Oil LubricationAcademics
Next generation inductively coupled plasma optical emission spectrometer.
Microwave induced nitrogen plasma source coupled to research grade spectrometer for simultaneous measurement of periodic table.
No chiller or argon required.
Small, lightweight design goes from box to bench installation in less than an hour.
MICAP+RIS Product Image
The current situation
 Analytical testing, equipment necessary
Graph image of mining sequence
1
Prospecting / Survey
Direct or indirect, quantitative measurements not used
2
Exploration 
Environmental and safety
3
Design Planning 
Core sampling
4
Development
Core sampling
5
Production 
Core sampling
6
Closure / Reclamation 
Core sampling
7
Heavy Machinery Maintenance 
Core sampling
The world's smallest ICP
Smarter. Faster. More efficient.
Radom’s proprietary Cerawave™ technology sets a new standard for productivity. Cerawave, an advanced ceramic ring, replaces water cooled coils and traditional RF generators. MICAP-OES 1000 is a powerful analytical instrument with a simple design eliminating the need for a chiller and permanent installation location.
Cerawave Ring Image
Icon Mobility

Mobility possibility

Exploration – setup for evaluation
Production
Remediation
Heavy machinery maintenance
Icon Nitrogen

Nitrogen technology

Less expensive to operate
Readily available
Safe to use
Can be generated from air

OREAS CRM results for gold in aqua regia digestions

AnalyteWavelengthCRM IDCertified ValuePreparation 1Preparation 2DilutionRecovery 1Recovery 2
Au, ppm267.5952382.952.992.841x101%96%
2428.336.957.281x83%87%
255b4.083.823.771x94%92%
256b7.587.617.131x100%94%
257b14.1714.5515.421x103%94%

Features & Benefits

What can our instruments do for you?
  • Use robust nitrogen plasma with superior matrix tolerance.
  • Simultaneous measurement for fast analysis times.
  • Smallest footprint and light-weight design.
  • Reduced running cost/analysis.
  • Easy-to-use Windows-based graphical user interface of RIS software package.
  • The ability to display, store and recall spectra for every sample analyzed data display and reprocessing, without the need to rerun samples (original data is unchanged).
  • Automated robust wavelength accuracy algorithm to ensure wavelength stability for extended sample runs.